Pesticide Residue Rapid Detection Reagent (500)

Pesticide Residue Rapid Detection Reagent (500)

Cat#
FSD-105
Product Name
Pesticide Residue Rapid Detection Reagent (500)
Product Overview
Pesticide Residue Rapid Detection Reagent (500) is designed for the detection of pesticide residue in vegetables.
Description
Pesticide Residue Rapid Detection Reagent (500) is designed for the detection of pesticide residue in vegetables. This reagent has the characteristic of well stability and high sensitivity, and could be used on various types of pesticide detecting instrument.
Notes
1, Pesticide residue test reagent include 10 packages of buffer powder, 10 bottles of cholinesterase, 2 bottles of Chromogenic reagent, and 4 bottles of substrates. All these item could offer 500 times detection.
2, When using any reagent, please exhaust the open one before reopening a new one in case they go bad.
3, Biochemical reaction will occur immediately when enzyme, substrate and chromogenic reagent meet together. So pipette and container should be labeled ,used alone in order to avoid cross-contamination .
4, When sucking the reagent from the bottle, it is strictly forbidden to inject the reagent back to the bottle.
5, Control the speed of action during using pipettor to suck reagent or drop reagent , in case the quantity of reagent is not accurate. Besides, it is helpful to protect the pipettor.
6, Inhibition rate could be calculated by formula: [( ΔΑ 0 -ΔΑ t )/ ΔΑ 0 ]×100%;
7, Normally, Inhibition rate could be calculated by pesticide detecting instrument automatically,
8, Inhibition rate≥50%: Positive result, it is recommended to detect again with gas chromatography.
9, Inhibition rate≤50%: Negative result.
Storage
This kind of pesticide residue rapid test reagent is very stable, and it can be transported in room temperature. For long term storage, it should be stored at 4 ℃, and the expiration time is 12 months. If it is stored in room temperature or normal temperature, the expiration time is 3-6 months.
Scientific Background
Pesticide of organophosphorus and carbamate could inhibit the activity of cholinesterase under certain conditions. Whether the samples contain organophosphorus or carbamate could be determined through the calculation of inhibition rate, which has positive correlation with pesticide concentration .
Detection method
Rapid Detection
Features & Benefits
Pesticide Residue Rapid Detection Reagent (500) can be used in various types of pesticide detecting instrument and spectrophotometer.
Sensitivity
The detection limits of Pesticide Residue Rapid Detection Reagent (500) to several commonly used pesticides are as follows (Unit: mg/kg):
Name of Pesticide Lowest Detection Limit
Dichlorvos 0.01
Carbosulfan 0.05
Phoxim 0.1
Methamidophos 0.2
Dursban 0.5
Malathion 0.5
Dimethoate 1.0
Omethoate 0.6
Methomyl 0.1
Dipterex 0.1
Carbofuran 0.05
Parathion 0.4
Sample Type
Vegetables
Our products/services are For Research Use Only. Not For Clinical Use!
Online Inquiry
0
Inquiry Basket